Finally, some information has come out on the use of the buttons (OPS and ID) on the UR93. To reset the UR93 to factory defaults do the following:
- Plug a throttle directly into the UR93 (no UP5 panel here!)
- Press the OPS button on the UR93 - the lights will flash
- On the throttle press SWITCH
- Enter 40 and press "c"(losed)
- Unplug the throttle from the UR93
- Finally, press the UR93's OPS button again
This resets the UR93 to its factory defaults. The author has tested this with DT402D, DT500D and DT602D throttles. All successfully reset the UR93.
Sadly still no information on the UR93's ID button.